20 / 25 kV Kilovac H-19 Make & Break Load Switching Features: 20 kV operating voltage Vacuum dielectric and tungsten contacts for power switching low current loads Double pole, double throw contacts Available with corona shield connectors Meets requirements of MIL-R-83725 Kilovac H-17 Make & Break Load Switching Features: Will isolate 12 kV at 32 MHz Tungsten contacts suitable for power switching low current loads Available with corona shield connectors Meets requirements of MIL-R-83725 QPL version available, M83725/2 Part Number PRODUCT SPECIFICATIONS H-19 Units DPDT 2C H-17 SPDT C 30 25 20 15 12 30 16 10 8 500 1 2.5 0.015 25 25 20 55-500 -55 to +125 1 7 Nominal, Volts dc Drop-Out, Volts dc Coil Resistance (Ohms 10%) COIL DATA 12 8 .5 - 5 H-19 H-17 48 24 26.5 16 1 - 10 225 120 115 80 5 - 50 2100 2900 Contact Arrangement .......................................................... Contact Form ........................................................................ Test Voltage (dc or 60Hz) ................................................... Rated Operating Voltage ..................................................... dc or 60 Hz ..................................................................... 2.5 MHz ........................................................................... 16 MHz ............................................................................ 32 MHz ............................................................................ Continuous Carry Current , Maximum ............................... dc or 60 Hz ..................................................................... 2.5 MHz ........................................................................... 16 MHz ............................................................................ 32 MHz ............................................................................ Coil Hi-Pot (V RMS, 60 Hz) ........................................... Contact Capacitance ............................................................ Between Open Contacts ................................................. Open Contacts to Ground .............................................. Contact Resistance, Maximum ........................................... Operate Time, Maximum ..................................................... Release Time, Maximum ..................................................... Shock, 11 ms 1/2 Sine ........................................................ Vibration, 10 Gs Peak ......................................................... Operating Ambient Temperature Range ............................ Mechanical Life (Operations x 106) .................................... Weight, Nominal .................................................................. ohms ms ms Peak G's Hz o Pickup, Volts dc, Maximum kV Peak kV Peak 25 20 15 10 7 Ratings listed are for 25C, sea level conditions PART NUMBER SELECTION Sample Part No. HModel H-19 H-17 Coil Voltage Blank = 26.5 Vdc /12Vdc = 12 Vdc /115Vdc = 115 Vdc 17 /12Vdc Amps 30 18 9 6 500 pF 1 2.5 0.015 30 20 30 55-500 -55 to +125 1 8.5 COIL C Cycles oz. CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail info@kilovac.com / website www.ciitech.com 50 |
Price & Availability of H-19115VDC |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |